11 KV Vacuum Circuit Breaker (VCB) Panel
IEC 62271200 compliant 11 kV VCB switchgear for safe, reliable distribution with tested shortcircuit withstand and internalarc safety. Integrates metering, numerical relays, and SCADA for modern plants
Standard: IEC 62271200, internalarc safe
Use: Reliable 11 kV distribution and feeder protection
Features: Tested shortcircuit withstand, numerical relays, metering, SCADAready
Immediate Assistance
Building a Reliable
Technical Experience!
Ever since incorporation, we have been making our way through futuristic technology and ground-breaking innovations.
Product Description
Swastik’s 11 kV Vacuum Circuit Breaker (VCB) Panel is an IEC 62271200 compliant, metalclad switchgear assembly engineered for safe, reliable mediumvoltage distribution in Indian industrial environments. Designed with internalarc considerations, robust busbar systems, and segregated compartments, it delivers high uptime, easier maintenance, and seamless integration with modern protection, metering, and SCADA systems.
* Voltage class: 12 kV, 50 Hz; shorttime withstand up to 25/31.5 kA for 1–3 s (projectspecific).
* Safety: internal arc options (IAC AFL/AFLR), pressure-relief ducting, visible-break earthing, key/mechanical interlocks.
*Construction: metal-clad PM partitions, Form-4 segregation, IP4X external and IP2X internal protection levels.
*Control and protection: vacuum breakers with racking/test positions, numerical relays (OCR/EF/SEF, BFR), event logs and time stamping.
Technical Specifications
Comprehensive technical details and performance parameters
| Parameter | Specification |
|---|---|
| Application | Protection & Control of TRF. Feeder |
| Reference Standards | IEC 62271 – 1 & 200 |
| Operation Voltage | 36 KV |
| Operational Current | 630 A, 800 A, 1250 A, 1600 A, 2000 A, 2500 A, 3100 A |
| Phase / Frequency | 3 PH / 50 HZ |
| Insulation Level | 70 KV rms / 170 KV Peak |
| Short Time Rating | 31.5 KA For 3 Sec |
| Ingress Protection | IP-4X / IP 55 |
| Temperature Rise | 85 Degree Centigrade Maximum |
Related Products
FAQ'S
The 11 kV Vacuum Circuit Breaker panels are engineered to meet IEC 62271/200 requirements with options for Internal Arc Classification (IAC AFL/AFLR), verified IP protection levels, and documented routine/FAT testing for consultant and utility acceptance.
Typical configurations support 12 kV class systems with short-time withstand up to 25/31.5 kA for 1–3 seconds, coordinated with project fault levels; operating sequences and duty cycles are specified per application.
Panels use metalclad PM partitions with Form-4 segregation, pressure-relief paths, visible-break earthing switches, and mechanical/key interlocks, enabling safer isolation, test positions, and faster maintenance turnaround.
Yes. The solution supports numerical protection relays (OCR/EF/SEF, breaker-failure), multifunction energy meters, and seamless PLC/SCADA connectivity via common industrial protocols for alarms, logs, and remote control.
Each delivery includes GA, SLD, wiring schematics, nameplate schedules, and O&M manuals, along with routine test reports; support covers design review, FAT scheduling, commissioning assistance, and genuine spares for lifecycle reliability.